Lincoln-electric INVERTEC SVM129-B Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Accessoires pour bateaux Lincoln-electric INVERTEC SVM129-B. Lincoln Electric INVERTEC SVM129-B User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 145
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
SVM129-B
April, 2011
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However,
your overall safety can be
increased by proper installation .
. . and thoughtful operation on
your part. DO NOT INSTALL,
OPERATE OR REPAIR THIS
EQUIPMENT WITHOUT READ-
ING THIS MANUAL AND THE
SAFETY PRECAUTIONS CON-
TAINED THROUGHOUT. And,
most importantly, think before
you act and be careful.
For use with machine code numbers:10151,10152,10153,10309,10381,10382,10383,11090,11091,11092,
11115,11116
INVERTEC
®
STT
®
& STT
®
II
SERVICE MANUAL
Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 1-888-935-3877 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
World's Leader in Welding and Cutting Products
Copyright © Lincoln Global Inc.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
View Safety Info View Safety Info View Safety Info View Safety Info
RETURN TO MAIN MENU
Vue de la page 0
1 2 3 4 5 6 ... 144 145

Résumé du contenu

Page 1 - & STT

SVM129-BApril, 2011Safety Depends on YouLincoln arc welding and cuttingequipment is designed and builtwith safety in mind. However,your overall safet

Page 2 - MAGNETIC FIELDS

INSTALLATIONA-4 A-4INVERTEC® STT® & STT® IIELECTRIC SHOCK can kill.• Only qualified personnel should perform this installation.• Turn the input po

Page 3 - ELECTRIC SHOCK can kill

TROUBLESHOOTING & REPAIRF-62 F-62INVERTEC® STT® & STT® IISWITCH BOARD REPLACEMENT (continued)TEST AFTER REPAIR OF SWITCHBOARDS AND/OR CAPACITO

Page 4

TROUBLESHOOTING & REPAIRF-63 F-63INVERTEC® STT® & STT® IISWITCH BOARD REPLACEMENT (continued)ELECTRIC SHOCK cankill.• With input power ON, the

Page 5 - REDRESSEUR

NOTESF-64 F-64INVERTEC® STT® & STT® IIReturn to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC

Page 6 - RETURN TO MAIN MENU

CAPACITOR REMOVAL ANDREPLACEMENT PROCEDUREService and repair should be performed by only Lincoln Electric factory trained personnel.Unauth

Page 7 - - INSTALLATION SECTION

TROUBLESHOOTING & REPAIRF-66 F-66INVERTEC® STT® & STT® IICAPACITOR REMOVAL AND REPLACEMENT PROCEDURE (continued)FIGURE F.30 – OUTPUT CHOKE LEA

Page 8

TROUBLESHOOTING & REPAIRF-67 F-67INVERTEC® STT® & STT® IICAPACITOR REMOVAL AND REPLACEMENT PROCEDURE (continued)FIGURE F.31 – PLUG J1 DISCONNE

Page 9

TROUBLESHOOTING & REPAIRF-68 F-68INVERTEC® STT® & STT® IICAPACITOR REMOVAL AND REPLACEMENT PROCEDURE (continued)FIGURE F.33 – STT PLACED ON IT

Page 10 - INSTALLATION

TROUBLESHOOTING & REPAIRF-69 F-69INVERTEC® STT® & STT® IICAPACITOR REPLACEMENTNOTE: Capacitors must always be replaced inmatched sets (C

Page 11

TROUBLESHOOTING & REPAIRF-70 F-70INVERTEC® STT® & STT® II15. Place the machine on its side as shown inFigure F.35. Slide the plastic

Page 12

TROUBLESHOOTING & REPAIRF-71 F-71INVERTEC® STT® & STT® II17. Remove the two 7/16” hex bolts that hold thecapacitor to the switch board.

Page 13 - - OPERATION SECTION

INSTALLATIONA-5 A-5INVERTEC® STT® & STT® IIINPUT CABLE INSTALLATION AND CON-NECTIONA cable strain relief is provided at the supply line entryand

Page 14 - OPERATION

TROUBLESHOOTING & REPAIRF-72 F-72INVERTEC® STT® & STT® II19. Install the new capacitor and tighten the two7/16” hex bolts to a torque of 55 in

Page 15

OUTPUT RECTIFIER REMOVAL AND REPLACEMENTService and repair should be performed by only Lincoln Electric factory trained personnel.Unauthor

Page 16

TROUBLESHOOTING & REPAIRF-74 F-74INVERTEC® STT® & STT® IIOUTPUT RECTIFIER REMOVAL AND REPLACEMENT (continued)FIGURE F.39 – CHOKE LEAD/HEAT SI

Page 17

TROUBLESHOOTING & REPAIRF-75 F-75INVERTEC® STT® & STT® IIOUTPUT RECTIFIER REMOVAL AND REPLACEMENT (continued)FIGURE F.40 – MAIN TRANSFORMER D

Page 18

TROUBLESHOOTING & REPAIRF-76 F-76INVERTEC® STT® & STT® IIOUTPUT RECTIFIER REMOVAL AND REPLACEMENT (continued)FIGURE F.41 – SWITCH BOARD/CAPAC

Page 19

RETEST AFTER REPAIRRetest the INVERTEC® STT® & STT® II:• If it fails any test and the test requires removing or replacing any mechanical part tha

Page 20

INPUT FILTER CAPACITOR CONDITIONINGIf the machine will not produce output when turned onand the following two conditions exist:The machine is conne

Page 21 - - ACCESSORIES

INVERTEC® STT® & STT® IISection G-1 Section G-1TABLE OF CONTENTS- ELECTRICAL DIAGRAMS SECTION -Electrical Diagrams...

Page 22 - ACCESSORIES

  77 7+ -ELE CTRIC AL S YMB OLS P ER E1 537H1T1 FANMOTORGFEJAIKCDMLBNH7576773132414224818221GNDSPARE42VACT3 CU

Page 23

  77 7R32A32B1516J22RB18V32C43ARU318V501B504W455275186331110J61212A97212352212B503AY30130524522381131350324V351

Page 24

A-6INSTALLATION A-6INVERTEC® STT® & STT® II IIFIGURE A.2 RECONNECT PANELINPUT VOLTAGE RECONNECTPROCEDUREAs shipped from the factory, multiple vo

Page 25 - -MAINTENANCE

  77 7R32A32B1516J22RB18V32C43ARU318V501B504W455275186331110J61212A97212352212B503AY30130524522381131350324V351

Page 26 - MAINTENANCE

  77 7+-ELECTRICALSYMBOLSPER E153712341 34616105{1485H1T1 FANMOTORGFEJAIKCDMLBNH7576773132414224818221GNDSPARE4

Page 27

  77 7J281150V0.1C41 3+15 V_REM50V0.1C41 1+15 V_REMREMREM3.9 2KR46 3MET ER_2MET ER_1PB_ SCALE D1.0 0KR43 63.9 2

Page 28

  77 7$)&,"2*$.-20.+8."0%.%&1)&&2.'

Page 29 - -THEORY OF OPERATION SECTION

  77 78."0%11&,#+6.-20.+.%&1 Lincoln Electric assumes no re

Page 30 - THEORY OF OPERATION

  77 7$)&,"2*$.-20.+8."0%.%&1)&&2.'

Page 31

  77 7$)&,"2*$.-20.+8."0%.%&1)&&2.&apos

Page 32

  77 7G4648-2INVERTERWELDERSCONTROL P.C. BOARD ASSEMBLY1:1G4648-1DO NOTSCALETHIS DRAWINGEQUIPMENTTYPE:SUBJECT:SCAL

Page 33

  77 7$)&,"2*$.5&08."0%++.%&1 Lincoln Electric assume

Page 34

  77 7L8033-8INVERTEC & METAL CUTTERSPOWER P.C. BOARD ASSEMBLYNONEL8033-7FI-UNLESSOTHERWISE SPECIFIED TOLERANC

Page 35

Section B-1 Section B-1INVERTEC® STT® & STT® IITABLE OF CONTENTS- OPERATION SECTION -Operation...

Page 36 - THEORY OF OPERATIONS

  77 7ON 2 PLACE DECIMALS IS + .O2WITH PUBLISHED STANDARDSON HOLES SIZES PER E-2056SUPPLYPOWERCh'ge.Sht.N

Page 37

  77 7 J12 J13R15R18R17 R16 R14 R13 R10 R12 R9 R11DZ1C17Q1R6D4 D1D3 D2R1 C12 C15C16OCI1D5R3R2D10D11D12D13R8D6D7 D8

Page 38

  77 7$)&,"2*$80*4&."0%.%&1 Lincoln Ele

Page 39

  77 7L12145-2STT II WELDERS IGBTDRIVEPC BD ASSEMBLYNONEL12145-1DO NOT SCALE THISDRAWINGEQUIPMENTTYPE:SUBJECT:UFCR

Page 40

  77 7WWR600mA40VQ71W3.3VDZ51.00KR121/2W1R15100V1AQ2600mA40VQ615.0KR1050V2700pC247.5R351N4936D9600mA40VQ51W10V

Page 41

  77 78."0%11&,#+65*2$)++.%&1 Lincoln Electric assumes no responsibilit

Page 42

  77 7$)&,"2*$0*4&0."0%++.%&1 Lincoln Electric assumes

Page 43 - TROUBLESHOOTING & REPAIR

  77 78."0%11&,#+60*4&0++.%&1 Lincoln Electric assumes no responsib

Page 44

  77 7$)&,"2*$0.2&$2*.-8."0%.%&1 Lincoln

Page 45

  77 78."0%11&,#+60.2&$2*.-.%&1 Lincoln Electric assume

Page 46

B-2 B-2INVERTEC® STT® & STT® IIELECTRIC SHOCKcan kill.• Do not touch electrically live partsor electrode with skin or wetclothing.• Insulate yours

Page 47

  77 7$)&,"2*$0.2&$2*.-8."0%.%&1 Lincoln

Page 48

  77 7L12235-2INVERTER WELDERSPROTECTION PC BOARD ASSEMBLY1:1L12235-1FEI-UNLESSOTHERWISE SPECIFIED TOLERANCEMANUFA

Page 49

  77 7$)&,"2*$300&-2&-1&8."0%++.%&1 Lincoln

Page 50

  77 78."0%11&,#+6300&-2&-1&++.%&1 Lincoln Electric assu

Page 51

  77 7$)&,"2*$&,.2&0.2&$2*.-8."0%++.%&1 Lin

Page 52

  77 78."0%11&,#+6&,.2&0.2&$2*.-++.%&1 Lincoln Electric a

Page 53 - RECONNECT PANEL

OPERATIONB-3 B-3INVERTEC® STT® & STT® IIGENERAL DESCRIPTIONThe Invertec STT II is a 225-ampere inverter based arcwelding power source specifically

Page 54

OPERATIONB-4 B-4INVERTEC® STT® & STT® II1. POWER SWITCH: Turns outputpower ON and OFF. This switchalso controls auxiliary poweravailable thr

Page 55

OPERATIONB-5 B-5INVERTEC® STT® & STT® II6. WIRE SIZE SELECT SWITCH: This toggle switchselects between electrode diameters of .035” (1 mm)and s

Page 56 - F-18 F-18

OPERATIONB-6 B-6INVERTEC® STT® & STT® IIWELDING PARAMETERS AND GUIDE-LINESThe Invertec STT II is neither a constant current (CC)nor a constant

Page 57

OPERATIONB-7 B-7INVERTEC® STT® & STT® IIWELDING PROCEDURES FOR STT II -(Steel) Horizontal Fillet (See Table B.1 and B.2)Table B.1 100% CO2 Gas Shi

Page 58

INVERTEC®STT®& STT®IISAFETYi iFOR ENGINEpowered equipment.1.a. Turn the engine off before troubleshooting and maintenancework unless the maintenan

Page 59

NOTESB-8 B-8INVERTEC® STT® & STT® IIReturn to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Re

Page 60

TABLE OF CONTENTS- ACCESSORIES -Accessories ...

Page 61

ACCESSORIESC-2 C-2INVERTEC® STT® & STT® IIGROUND inputs on this connector rather than fromthe front panel controls. If this short is removed, th

Page 62

ACCESSORIESC-3 C-3INVERTEC® STT® & STT® IILN-742 or STT-10 WIRE FEEDERCONNECTION INSTRUCTIONSThe LN-742 or STT-10 is the recommended wire feed

Page 63

C-4 C-4INVERTEC® STT® & STT® IIACCESSORIES CONNECTION DIAGRAM - INVERTEC STT II 4-9-99 M17657-3CABLES AND LEADS SHOULDELECTRODE LEADBE T

Page 64

Section D-1 Section D-1INVERTEC® STT® & STT® IITABLE OF CONTENTS-MAINTENANCE-Maintenance...

Page 65

MAINTENANCED-2 D-2INVERTEC® STT® & STT® IIWARNINGFailure to follow thiscapacitor discharge proce-dure can result in electricshock.INPUT FILTER CAP

Page 66 - F-28 F-28

MAINTENANCED-3 D-3INVERTEC® STT® & STT® IIPREVENTIVE MAINTENANCE1. Perform the following preventive mainte-nance procedures at least once every si

Page 67

MAINTENANCED-4 D-4INVERTEC® STT® & STT® II12417569871016151318141911132FIGURE D.2 – MAJOR COMPONENT LOCATIONS1. BASE ASSEMBLY2. REAR NAMEPLATE3. R

Page 68 - SWITCHSWITCH

Section E-1 Section E-1INVERTEC® STT® & STT® IITheory of Operation ...

Page 69

SAFETYii iiINVERTEC® STT® & STT® IIFUMES AND GASEScan be dangerous.5.a. Welding may produce fumes and gaseshazardous to health. Avoid breathi

Page 70 - F-32 F-32

GENERAL DESCRIPTIONThe INVERTEC® STT® & STT® II is a 225 ampere,inverter based, arc welding power supply specificallydesigned for the

Page 71

RECONNECT, PROTECTIONBOARD, RECTIFICATION ANDPRECHARGEThe reconnect panel allows the user to switch to low orhigh input voltage to match the input lin

Page 72

THEORY OF OPERATIONE-4 E-4INVERTEC® STT® & STT® IINOTE: Unshaded areas of Block Logic Diagram are the subject of discussion.FIGURE E.4 – SWITCH B

Page 73

THEORY OF OPERATIONE-5 E-5INVERTEC® STT® & STT® IIFIGURE E.5 – MAIN TRANSFORMER, OUTPUT RECTIFICATION AND CHOKEMAIN TRANSFORMER, OUTPUTRECTIFICATI

Page 74

THEORY OF OPERATIONE-6 E-6INVERTEC® STT® & STT® IIFIGURE E.6 – CONTROL BOARD, IGBT DRIVE AND MODULECONTROL BOARD, IGBT DRIVEAND MODULEThe control

Page 75

THEORY OF OPERATIONE-7 E-7INVERTEC® STT® & STT® IIFIGURE E.7 – POWER BOARD AND REMOTE PROTECTION BOARDPOWER BOARDThe power board creates a pulse t

Page 76

FIELD EFFECT TRANSISTOR (FET)OPERATIONAn FET is a type of transistor. FETs are semiconduc-tors well suited for high-frequency switching.Drawing A ab

Page 77

PULSE WIDTH MODULATIONThe term PULSE WIDTH MODULATION is used todescribe how much time is devoted to conduction inthe positive and n

Page 78 - F-40 F-40

PROTECTIVE CIRCUITSProtective circuits are designed into the Invertecmachine to sense trouble and shut down the machinebefore the trouble damage

Page 79

Section F-1 Section F-1INVERTEC® STT® & STT® IITroubleshooting & Repair Section ...

Page 80 - PC BOARD

INVERTEC® STT® & STT® IISAFETYiii iiiFOR ELECTRICALLYpowered equipment.8.a. Turn off input power using the disconnectswitch at the fuse box before

Page 81

HOW TO USE TROUBLESHOOTING GUIDEService and repair should be performed by only Lincoln Electric Factory Trained Personnel.Unauthorized rep

Page 82

ELECTRIC SHOCK can kill.Have an electrician install and servicethis equipment. Turn the machine OFFbefore working on equipment. Do n

Page 83

TROUBLESHOOTING & REPAIRF-4 F-4INVERTEC® STT® & STT® IIObserve Safety Guidelines TROUBLESHOOTING GUIDEdetailed in the beginning of this manual

Page 84

TROUBLESHOOTING & REPAIRF-5 F-5INVERTEC® STT® & STT® IITROUBLESHOOTING GUIDE Observe Safety Guidelinesdetailed in the beginning of this manual

Page 85

TROUBLESHOOTING & REPAIRF-6 F-6INVERTEC® STT® & STT® IIObserve Safety Guidelines TROUBLESHOOTING GUIDEdetailed in the beginning of this manual

Page 86 - F-48 F-48

TROUBLESHOOTING & REPAIRF-7 F-7INVERTEC® STT® & STT® IITROUBLESHOOTING GUIDE Observe Safety Guidelinesdetailed in the beginning of this manual

Page 87

F-8 F-8INVERTEC® STT® & STT® IITROUBLESHOOTING & REPAIRTROUBLESHOOTING GUIDE Observe Safety Guidelinesdetailed in the beginning of this manual

Page 88

TROUBLESHOOTING & REPAIRF-9 F-9INVERTEC® STT® & STT® IIObserve Safety Guidelines TROUBLESHOOTING GUIDEdetailed in the beginning of this manual

Page 89

TROUBLESHOOTING & REPAIRF-10 F-10INVERTEC® STT® & STT® IITROUBLESHOOTING GUIDE Observe Safety Guidelinesdetailed in the beginning of this manu

Page 90

TROUBLESHOOTING & REPAIRF-11 F-11INVERTEC® STT® & STT® IIObserve Safety Guidelines TROUBLESHOOTING GUIDEdetailed in the beginning of this manu

Page 91

SAFETYiv ivINVERTEC® STT® & STT® IIPRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instructionset les précautions

Page 92

TROUBLESHOOTING & REPAIRF-12 F-12INVERTEC® STT® & STT® IITROUBLESHOOTING GUIDE Observe Safety Guidelinesdetailed in the beginning of this manu

Page 93 - PLUG J22

TROUBLESHOOTING & REPAIRF-13 F-13INVERTEC® STT® & STT® IIT1 AUXILIARY TRANSFORMER TESTWARNINGService and repair should be performed by only Li

Page 94

TROUBLESHOOTING & REPAIRF-14 F-14INVERTEC® STT® & STT® IIT1 AUXILIARYTRANSFORMERPLUGJ31PLUGJ30FIGURE F.1 – T1 AUXILIARY TRANSFORMER AND J30/J3

Page 95

TROUBLESHOOTING & REPAIRF-15 F-15INVERTEC® STT® & STT® II5. Locate the primary lead molex plug (J21)just behind the reconnect panel ass

Page 96 - F-58 F-58

TEST POINTSPLUG J30 PINS 1 TO 2 (LEADS 32 TO 33)PLUG J31 PINS 1 TO 4 (LEADS 501 TO 504)PLUG J31 PINS 2 TO 3(LEADS 212 TO 503)PLUG J31 PINS 2 TO 5(

Page 97

TROUBLESHOOTING & REPAIRF-17 F-17INVERTEC® STT® & STT® IIELECTRIC SHOCK cankill.• With input power ON,there are high voltagesinside the

Page 98

NOTESF-18 F-18INVERTEC® STT® & STT® IIReturn to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC

Page 99

T4 AUXILIARY TRANSFORMER TESTService and repair should be performed by only Lincoln Electric factory trained personnel.Unauthorized repair

Page 100 - TROUBLESHOOTING & REPAIR

TROUBLESHOOTING & REPAIRF-20 F-20INVERTEC® STT® & STT® IIT4 AUXILIARY TRANSFORMER TEST (continued)FIGURE F.3 – OUTPUT CHOKE/IGBT MODULE SPLIC

Page 101

TROUBLESHOOTING & REPAIRF-21 F-21INVERTEC® STT® & STT® IIT4 AUXILIARY TRANSFORMER TEST (continued)5. Disconnect the current sensing Plug J1 f

Page 102 - INVERTEC® STT® & STT® II

MASTER TABLE OF CONTENTS FOR ALL SECTIONSv vINVERTEC® STT® & STT® IIPageSafety ...

Page 103

TROUBLESHOOTING & REPAIRF-22 F-22INVERTEC® STT® & STT® IIT4 AUXILIARY TRANSFORMER TEST (continued)7. Carefully lift and tilt the INVERTEC® ST

Page 104

TROUBLESHOOTING & REPAIRF-23 F-23INVERTEC® STT® & STT® IIT4 AUXILIARY TRANSFORMER TEST (continued)11. Locate and remove leads #32A, #32B and#

Page 105

13. Check the secondary AC voltages accord-ing to Table F.2.14. With the correct 115VAC applied to the pri-mary winding (#32 to #33), if any or all

Page 106 - BOLTS (5)

INPUT RECTIFIER TESTService and repair should be performed by only Lincoln Electric factory trained personnel.Unauthorized repairs performe

Page 107

TROUBLESHOOTING & REPAIRF-26 F-26INVERTEC® STT® & STT® IIINPUT RECTIFIER TEST (continued)FIGURE F.9 - INPUT RECTIFIER LOCATIONINPUTRECTIFIERCA

Page 108

6. Replace the input rectifier when any of thetests are NOT OK.NOTE: When installing a new input rectifier,torque the mounting nuts (in a c

Page 109

NOTESF-28 F-28INVERTEC® STT® & STT® IIReturn to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC

Page 110

CAPACITOR BALANCE TESTService and repair should be performed by only Lincoln Electric factory trained personnel.Unauthorized repairs perfo

Page 111

TROUBLESHOOTING & REPAIRF-30 F-30INVERTEC® STT® & STT® IICAPACITOR BALANCE TEST (continued)FIGURE F.10 – SWITCH BOARD TEST POINTSL8441L8441SW

Page 112 - CHOKE LEAD

5. Adjust the Peak and Background controls tothe minimum settings (controls on casefront).6. Jumper together pins "C" and "D&quo

Page 113 - SECONDARY

TABLE OF CONTENTS- INSTALLATION SECTION -Section A-1 Section A-1INVERTEC® STT® & STT® IIInstallation...

Page 114 - THROUGH-BOLTS

NOTESF-32 F-32INVERTEC® STT® & STT® IIReturn to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC

Page 115

SWITCH BOARD TESTService and repair should be performed by only Lincoln Electric factory trained personnel.Unauthorized repairs performed

Page 116

TROUBLESHOOTING & REPAIRF-34 F-34INVERTEC® STT® & STT® IISWITCH BOARD TEST (continued)FIGURE F.11 - SWITCH BOARD RESISTANCE TESTTEST PROCEDURE

Page 117 - TABLE OF CONTENTS

TROUBLESHOOTING & REPAIRF-35 F-35INVERTEC® STT® & STT® IISWITCH BOARD TEST (continued)Apply Positive Apply NegativeTest Probe to Test Probe to

Page 118 -  

TROUBLESHOOTING & REPAIRF-36 F-36INVERTEC® STT® & STT® IIApply Positive Apply NegativeTest Probe to Test Probe toTerminal Terminal Test Result

Page 119

SNUBBER RESISTORS TESTService and repair should be performed by only Lincoln Electric factory trained personnel.Unauthorized repairs perfo

Page 120

TROUBLESHOOTING & REPAIRF-38 F-38INVERTEC® STT® & STT® IISNUBBER RESISTORS TEST (continued)FIGURE F.12 - REMOVING LEADSTEST PROCEDURE1. Turn

Page 121

TROUBLESHOOTING & REPAIRF-39 F-39INVERTEC® STT® & STT® IISNUBBER RESISTORS TEST (continued)FIGURE F.13 - SWITCH BOARD TEST POINTS6. Test for

Page 122

NOTESF-40 F-40INVERTEC® STT® & STT® IIReturn to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC

Page 123

POWER BOARD TESTService and repair should be performed by only Lincoln Electric factory trained personnel.Unauthorized repairs performed o

Page 124

RECOMMENDED INPUT WIRE AND FUSE SIZESINSTALLATIONA-2 A-2INVERTEC® STT® & STT® IISTANDARD VOLTAGE INPUT CURRENT AT RATED OUTPUT208/230/460/3/60 HZ

Page 125

TROUBLESHOOTING & REPAIRF-42 F-42INVERTEC® STT® & STT® IIPOWER BOARD TEST (continued)FIGURE F.14 – REMOVING THE FRONT PANEL ASSEMBLYPOWERPC BO

Page 126

TROUBLESHOOTING & REPAIRF-43 F-43INVERTEC® STT® & STT® IIPOWER BOARD TEST (continued)FIGURE F.15 – POWER PC BOARD TEST POINTSPOWER BOARDJ6J7J1

Page 127 - G4648-2B0

TROUBLESHOOTING & REPAIRF-44 F-44INVERTEC® STT® & STT® IIPOWER BOARD TEST (continued)FIGURE F.16 – SIMPLIFIED TRIGGER CIRCUITFROM PROTECTIONBO

Page 128

PROTECTION BOARD TESTService and repair should be performed by only Lincoln Electric factory trained personnel.Unauthorized repairs perfor

Page 129

TROUBLESHOOTING & REPAIRF-46 F-46INVERTEC® STT® & STT® IIPROTECTION BOARD TEST (continued)FIGURE F.17 – PROTECTION PC BOARD TEST POINTSPROTECT

Page 130

TROUBLESHOOTING & REPAIRF-47 F-47INVERTEC® STT® & STT® IIFIGURE F.18 - LEADS #309, #309A AT CR1, CR2 RELAYSCR2CR1309A309PROTECTION BOARD TEST

Page 131

NOTESF-48 F-48INVERTEC® STT® & STT® IIReturn to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC

Page 132

TRIGGER CIRCUIT TESTService and repair should be performed by only Lincoln Electric factory trained personnel.Unauthorized repairs perform

Page 133

TROUBLESHOOTING & REPAIRF-50 F-50INVERTEC® STT® & STT® IITRIGGER CIRCUIT TEST (continued)FIGURE F.19 – PLUG J31 LOCATIONPLUGJ31TEST PROCEDURE1

Page 134

TROUBLESHOOTING & REPAIRF-51 F-51INVERTEC® STT® & STT® IITRIGGER CIRCUIT TEST (continued)FIGURE F.20 – 14 PIN AMPHENOL AND PLUG J31 PIN ASSIGN

Page 135

INSTALLATIONA-3 A-3INVERTEC® STT® & STT® IISTANDARD VOLTAGE INPUT CURRENT AT RATED OUTPUT200/208/3/50/60 HZ 36/34200/208/380/400/415/3/50/60 HZ 36

Page 136

TROUBLESHOOTING & REPAIRF-52 F-52INVERTEC® STT® & STT® IITRIGGER CIRCUIT TEST (continued)FIGURE F.22 – SIMPLIFIED TRIGGER CIRCUIT DIAGRAMFROM

Page 137

IGBT MODULEREMOVAL AND REPLACEMENTService and repair should be performed by only Lincoln Electric factory trained personnel.Unauthorized r

Page 138

TROUBLESHOOTING & REPAIRF-54 F-54INVERTEC® STT® & STT® IIIGBT MODULE REMOVALAND REPLACEMENT (continued)FIGURE F.23 – OUTPUT CHOKE LEAD DISCONN

Page 139

TROUBLESHOOTING & REPAIRF-55 F-55INVERTEC® STT® & STT® IIIGBT MODULE REMOVALAND REPLACEMENT (continued)FIGURE F.24 – PLUG J1 DISCONNECTIONLOWE

Page 140

TROUBLESHOOTING & REPAIRF-56 F-56INVERTEC® STT® & STT® IIIGBT MODULE REMOVALAND REPLACEMENT (continued)FIGURE F.26 – STT PLACED ON ITS RIGHT S

Page 141 - L12235-2B0

TROUBLESHOOTING & REPAIRF-57 F-57INVERTEC® STT® & STT® IIIGBT MODULE REMOVALAND REPLACEMENT (continued)FIGURE F.27 – IGBT MODULE CONNECTIONSEE

Page 142

NOTESF-58 F-58INVERTEC® STT® & STT® IIReturn to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC

Page 143 - REVISION CONTROL

SWITCH BOARDREPLACEMENTService and repair should be performed by only Lincoln Electric factory trained personnel.Unauthorized repairs perf

Page 144

TROUBLESHOOTING & REPAIRF-60 F-60INVERTEC® STT® & STT® IISWITCH BOARD REPLACEMENT (continued)FIGURE F.28 – SWITCH BOARD REMOVALPROCEDURENOTE:

Page 145

TROUBLESHOOTING & REPAIRF-61 F-61INVERTEC® STT® & STT® IISWITCH BOARD REPLACEMENT (continued)6. Using the 7/16" wrench, remove the two h

Commentaires sur ces manuels

Pas de commentaire