Lincoln-electric IM465 INVERTEC DC TIG STARTER Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Lincoln-electric IM465 INVERTEC DC TIG STARTER. Lincoln Electric IM465 INVERTEC DC TIG STARTER User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 33
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
INVERTEC DC TIG STARTER
OPERATOR’S MANUAL
This manual for use with DC TIG Starter Codes 9926, 9990 & 10368
IM465-B
October, 1999
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However, your
overall safety can be increased by
proper installation ... and thought-
ful operation on your part. DO
NOT INSTALL, OPERATE OR
REPAIR THIS EQUIPMENT
WITHOUT READING THIS
MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED
THROUGHOUT. And, most
importantly, think before you act
and be careful.
®
• Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
• World's Leader in Welding and Cutting Products •
RETURN TO MAIN MENU
Vue de la page 0
1 2 3 4 5 6 ... 32 33

Résumé du contenu

Page 1 - INVERTEC DC TIG STARTER

INVERTEC DC TIG STARTEROPERATOR’S MANUALThis manual for use with DC TIG Starter Codes 9926, 9990 & 10368IM465-BOctober, 1999Safety Depends on

Page 2 - MAGNETIC FIELDS

A-2INSTALLATION INVERTEC DC TIG STARTERA-2PRODUCT DESCRIPTIONThe purpose of the DC TIG Starter is to provide a highfrequency, high voltage pulse for

Page 3 - FUMES AND GASES

A-3INSTALLATION INVERTEC DC TIG STARTERA-3b. Keep the work and torch leads as short as possibleand as close together as possible. Lengths shouldnot

Page 4

A-4INSTALLATION INVERTEC DC TIG STARTERA-4Figure 2 below shows connection of water-cooledtorches with the required 7/8-RH to 5/8-RH adapter forthe g

Page 5 - REDRESSEUR

B-1OPERATION INVERTEC DC TIG STARTERB-1OPERATING INSTRUCTIONSELECTRIC SHOCK can kill.• Do not touch electrically live parts orelectrode with skin or

Page 6 - Thank You

B-2OPERATIONB-2INVERTEC DC TIG STARTERPower Source and Starter Kit OperationDuty CycleThe DC TIG Starter kit is rated to match the V300Invertec’s duty

Page 7 - TABLE OF CONTENTS

Trigger Function Switch:This switch selects a 2-stepor 4-step trigger function when used with an arc startswitch. This switch should be placed in the

Page 8

B-4OPERATIONB-4INVERTEC DC TIG STARTERFIGURE 32-Step Trigger Control Using Arc Start Switch4-STEP: In this mode, closing the trigger (or arc startswit

Page 9

C-1ACCESSORIESC-1There are no factory installed options. The DC TIGStarter comes complete with cables, torch adapters,and hardware for installation.Fi

Page 10 - INSTALLATION

D-1MAINTENANCED-1INVERTEC DC TIG STARTERRoutine Maintenance1. Every 6 months or so the machine should becleaned with a low pressure airstream. Keeping

Page 11

If for any reason you do not understand the test procedures or are unable to perform the necessarytests/repairs safely, contact your local authorized

Page 12

FOR ENGINEpowered equipment.1.a. Turn the engine off before troubleshooting and maintenancework unless the maintenance work requires it to be running.

Page 13 - OPERATION

E-2TROUBLESHOOTINGE-2INVERTEC DC TIG STARTERObserve all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the t

Page 14

E-3TROUBLESHOOTINGE-3INVERTEC DC TIG STARTERObserve all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the t

Page 15

E-4TROUBLESHOOTINGE-4INVERTEC DC TIG STARTERObserve all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the t

Page 16

E-5TROUBLESHOOTINGE-5INVERTEC DC TIG STARTERObserve all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the t

Page 17 - ACCESSORIES

E-6TROUBLESHOOTINGE-6INVERTEC DC TIG STARTEREnvironmental ProtectionHigh voltage connections are covered with an RTVsealant to prevent malfunction in

Page 18 - MAINTENANCE

F-1DIAGRAMSF-1INVERTEC DC TIG STARTER#'%#$#(#%& (

Page 19 - TROUBLESHOOTING

F-2DIAGRAMSF-2INVERTEC DC TIG STARTER,4(%!"#$%&"'(')*+),-

Page 20

F-3DIAGRAMSF-3INVERTEC DC TIG STARTER''.

Page 21

F-4DIAGRAMSF-4INVERTEC DC TIG STARTER

Page 22

NOTES INVERTEC DC TIG STARTER

Page 23

iiSAFETYiiARC RAYS can burn.4.a. Use a shield with the proper filter and coverplates to protect your eyes from sparks andthe rays of the arc when weld

Page 24

Now Available...12th EditionThe Procedure Handbook of Arc WeldingWith over 500,000 copies of previous editions publishedsince 1933, the Procedure Hand

Page 25 - DIAGRAMS

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicREAD AND UNDERSTAND THE MANUFACTURER’S INSTRUC

Page 26

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicLEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE

Page 27

• Sales and Service through Subsidiaries and Distributors Worldwide •Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB

Page 28

FOR ELECTRICALLYpowered equipment.8.a. Turn off input power using the disconnectswitch at the fuse box before working onthe equipment.8.b. Install equ

Page 29 - NOTES

ivSAFETYivPRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instructionset les précautions de sûreté specifiques qui parra

Page 30 - Lincoln Welding School

Thank Youfor selecting a QUALITY product by Lincoln Electric. We want youto take pride in operating this Lincoln Electric Company product••• as much p

Page 31

viTABLE OF CONTENTSPageInstallation ...Section ATe

Page 32

NOTES

Page 33

INPUTStandard Voltage/Frequency Input Current42 VAC ±15% / 50/60 Hz. 2.0 Amps - Rated OutputA-1INSTALLATION INVERTEC DC TIG STARTERA-1TECHNICAL SPEC

Commentaires sur ces manuels

Pas de commentaire