• Sales and Service through Subsidiaries and Distributors Worldwide •Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: w
A-3INSTALLATION POWER FEED™ 10A CONTROLLERA-3Auxiliary Input Power Connection Instructions:1. Remove two Phillips Head screws on right side offront
A-4INSTALLATION POWER FEED™ 10A CONTROLLERA-44. Replace the Switch Panel on the POWER FEED™10A CONTROLLER with the blank panel includedwith the pend
A-5INSTALLATION POWER FEED™ 10A CONTROLLERA-5INCH DOWN#47SWITCH GROUP#2 SUPPLY#43TRAVEL AUTO#44TRAVEL ON#45INCH UP#42SWITCH GROUP#1 SUPPLY#39START#4
A-6INSTALLATION POWER FEED™ 10A CONTROLLERA-68. Connect input supply voltage per the Auxiliary InputPower Connection Instructions listed earlier.9.
A-7INSTALLATION POWER FEED™ 10A CONTROLLERA-7POWER WAVEAC/DC 1000K2344-1K1543-XXARCLINK CONTROL CABLEWORK PIECEELECTRODESENSE LEADK1785-xx 14 — 14 P
A-8INSTALLATION POWER FEED™ 10A CONTROLLERA-8REMOTE SENSE LEAD SPECIFICATIONSWelding with Multiple ArcsSpecial care must be taken when more than one
B-1OPERATIONB-1POWER FEED™ 10A CONTROLLERSAFETY PRECAUTIONSRead this entire section of operating instructionsbefore operating the machine.ELECTR
B-2OPERATIONB-2POWER FEED™ 10A CONTROLLERPRODUCT DESCRIPTIONGeneral Physical DescriptionThe POWER FEED™ 10A CONTROLLER is a userinterface. The co
B-3OPERATIONB-3POWER FEED™ 10A CONTROLLERLOCATING FRONT PANEL CONTROLS AND INPUT, OUPUT CONNECTIONS5-PIN INPUTRECEPTACLE4-PIN TRAVEL RECEPTACLE14-PIN
B-4OPERATIONB-4CASE FRONT CONTROL DESCRIPTIONS1. DUAL DIGITAL DISPLAYS – Bright 7-segment dis-plays showing welding parameter settings and actu-al lev
FOR ENGINEpowered equipment.1.a. Turn the engine off before troubleshooting and maintenancework unless the maintenance work requires it to be running.
B-5OPERATIONB-5Blinking green Occurs during a reset and indi-cates the power source is identify-ing each component in the system.This is normal
B-6OPERATIONB-6WELD MODE DESCRIPTION1. Allows wireless machine configuration using a PalmOS based hand-held computer.2. Consists of easy to read 36 se
B-7OPERATIONB-7AC CONTROLPressing the Left Mode Select Panel Pushbutton whilein WELD MODE will illuminate the AC CONTROLLED (if AC parameters are av
B-8OPERATIONB-8END OPTIONSPressing the Right Mode Select Panel Pushbuttonafter scrolling through the Start Options will illuminatethe END OPTIONS LED
B-9OPERATIONB-9PARAMETERArc Delay TimeStrike Fault TimeStrike WFSStrike VoltsRestrike TimeStart WFS/AmpsStart VoltsStart TimeStart Arc ForceUpslope Ti
B-10OPERATIONB-10GENERAL SETUP MODE OPTIONSThe Setup Mode can be used to set more generalwelding configurations such as travel options or dis-play
B-11OPERATIONB-11INFRARED (IR) CONTROLThe Mode Select Panel interface includes an infraredtransceiver. This allows wireless machine configura-tion us
B-12OPERATIONB-12This panel performs these functions: limit setting andmemory saving/restoring. There are six user memo-ries.PROCEDURE MEMORY VS. USER
B-13OPERATIONB-13LIMIT SETTINGEach user memory can be optionally configured to limitthe user’s range of control over some user interface set-tings.
C-1ACCESSORIESC-1GENERAL OPTIONS / ACCESSORIESK2311-1 Power Feed 10SM-Converts NA style wiredrives into Power Feed-10S Wire DrivesK2370-1 Power Feed
iiSAFETYiiARC RAYS can burn.4.a. Use a shield with the proper filter and coverplates to protect your eyes from sparks andthe rays of the arc when weld
D-1MAINTENANCED-1ROUTINE MAINTENANCE• Check weld cables, control cables and gas hosesfor cuts.• Clean and tighten all weld terminals.• Inspect and
E-1TROUBLESHOOTINGE-1POWER FEED™ 10A CONTROLLERIf for any reason you do not understand the test procedures or are unable to perform the tests/repairs
E-2TROUBLESHOOTINGE-2POWER FEED™ 10A CONTROLLERIf for any reason you do not understand the test procedures or are unable to perform the tests/repairs
E-3TROUBLESHOOTINGE-3If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact yourLocal
E-4TROUBLESHOOTINGE-4POWER FEED™ 10A CONTROLLERIf for any reason you do not understand the test procedures or are unable to perform the tests/repairs
E-5TROUBLESHOOTINGE-5POWER FEED™ 10A CONTROLLERObserve all Safety Guidelines detailed throughout this manualIf for any reason you do not understand th
E-6TROUBLESHOOTINGE-6POWER FEED™ 10A CONTROLLERObserve all Safety Guidelines detailed throughout this manualIf for any reason you do not understand th
F-1DIAGRAMSF-1POWER FEED™ 10A CONTROLLERPOWER FEED 10A CONTROLLERJ3412345678910FLEXFLEXSWITCH GROUP #2 SUPPLY3-PIN FLUXRECEPTACLEABCDEABCJ33REMOTE P.C
F-2DIMENSION PRINTF-2POWER FEED™ 10A CONTROLLERWARNINGM20414 A14.121.95358.624.14.99126.711.68296.512.25311.213.25336.6
WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicREAD AND UNDERSTAND THE MANUFACTURER’S INSTRUC
iiiSAFETYiiiFOR ELECTRICALLYpowered equipment.8.a. Turn off input power using the disconnectswitch at the fuse box before working onthe equipment.8.b.
WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicLEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE
• Sales and Service through Subsidiaries and Distributors Worldwide •Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB
ivSAFETYivPRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instructionset les précautions de sûreté specifiques qui parra
vvTThhaannkk YYoouufor selecting a QUALITY product by Lincoln Electric. We want youto take pride in operating this Lincoln Electric Company product
vi vi TABLE OF CONTENTSPage––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Installation...
A-1GENERAL INFORMATION POWER FEED™ 10A CONTROLLERA-1TECHNICAL SPECIFICATIONS: POWER FEED™ 10A CONTROLLERSPEC.# TYPE 142:1 SPEED RA
A-2INSTALLATION POWER FEED™ 10A CONTROLLERA-2SAFETY PRECAUTIONWELDING VOLTAGEWire feed parts are electrically live while welding and whileinching wi