Lincoln Electric 355M Manuel d'utilisateur Page 116

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 137
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 115
OUTPUT RECTIFIER MODULES REMOVAL AND REPLACEMENT (con’t)
TROUBLESHOOTING AND REPAIR
F-70 F-70
POWER WAVE 355M/405M
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
PROCEDURE
1. Remove input power to the POWER WAVE
355M/405M.
2. Using a 5/16” nut driver remove the case wrap-
around cover.
3. Perform the Input Filter Capacitor Discharge
Procedure detailed earlier in this section.
4. Locate the output diode modules located behind
the snubber board. See figure F.32.
5. Before the output rectifier modules can be
reached, the Snubber Board Removal
Procedure must be performed.
6. After the snubber board is removed, remove the
four leads connected to the modules using a 3/16”
allen wrench. These leads are #X4, #X2, #20, #40.
Note their positions for reassembly. See Figure
F.33.
7. Remove the copper plates from the tops of the
modules.
NOTE: Any instructions that are packaged with the
replacement part will supercede these instruc-
tions.
LEFT SIDE
Snubber
Board
Output Diode
Modules
FIGURE F.32 OUTPUT RECTIFIER MODULE LEAD LOCATIONS
Vue de la page 115