Lincoln Electric 355M Manuel d'utilisateur Page 28

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 137
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 27
OPERATION
B-6 B-6
POWER WAVE 355M/405M
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TIG GTAW
The TIG mode features continuous control from 5 to
425 amps. The TIG mode can be run in either the
Touch Start TIG or Scratch start mode.
The Arc Control level selects the starting mode.
Between –10 and 0, the Touch Start TIG mode is
selected. The OCV is controlled below 10V and the
short circuit "TIG touch" current is maintained at
approximately 25 amps, independent of the preset
current. When the tungsten is lifted, an arc is initiated
and the output is regulated at the preset value. A set-
ting of 0, results in the most positive arc initiation. A
setting of -10 reduces the start procedure to start the
weld, and from there, to ramp to the welding proce-
dure over a specified amount of time.
A setting above 0 selects a Scratch Start. Full OCV is
available when the arc initiates the output is regulated
to the preset value
Typically starting procedure on a higher “+” setting is
known as a “Hot Start”. Setting a starting procedure
on a lower setting is known as a “Cold Start”.
Recommended Welding Procedures for Power Mode
NOTE: Later versions of weld software
eliminated the Arc Control Function
in TIG mode and only allow for
“Touch Start” operation.
SMAW
In SMAW (STICK mode), the arc control adjusts the
arc force. It can be set to the lower range (0 to -10) for
a soft and less penetrating arc characteristic or to the
higher range (0 to +10) for a crisp and more penetrat-
ing arc. Normally, when welding with cellulosic types of
electrodes (E6010, E7010, E6011), a higher energy
arc is required to maintain arc stability. This is usually
indicated when the electrode sticks to the work-piece
or when the arc pops-out during manipulative tech-
nique. For low hydrogen types of electrodes (E7018,
E8018, E9018, etc.) a softer arc is usually desirable
and the lower end of the Arc Control suits these types
of electrodes. In either case the arc control is available
to increase or decrease the energy level delivered to
the arc.
MATERIAL Aluminum 4043 Aluminum 5356 Mild Steel Mild Steel Mild Steel Mild Steel Mild Steel Mild Steel Stainless Steel Stainless Steel
WIRE E4043 E5356 L56 L56 L56 L56 L56 L56 E308L E308L
WIRE SIZE 0.035 0.035 0.025 0.025 0.030 0.030 0.035 0.035 0.030 0.035
GAS 100% Agr. 100% Agr.
100% CD
2
75/25 Ar/CO
2
100% CD
2
75/25 Ar/CO
2
100% CD
2
75/25 Ar/CO
2
Tri-mix Tri-mix
22 ga.
Not
recommended
100 / 0.8
Not
recommended
90 / 1.0
20 ga. 120 / 1.0 120 / 1.0 100 / 0.7 100 / 1.0 80 / 1.5 50 / 0.5
18 ga. 140 / 1.7 140 / 1.5 110 / 1.5 110 / 1.5 100 / 2.5 100 / 2.5 110 / 2.0 110 / 2.0
16 ga. 190 / 2.0 190 / 2.0 125 / 2.0 125 / 2.0 125 / 3.0 125 / 3.0 140 / 2.5 130 / 2.7
14 ga. 400 / 2.0 400 / 2.5 260 / 3.0 260 / 3.0 160 / 2.3 160 / 2.3 160 / 3.8 160 / 3.5 210 / 3.0 190 / 3.5
12 ga. 330 / 5.0 330 / 4.5 230 / 3.5 230 / 3.5 200 / 5.0 200 / 4.5 270 / 5.0 230 / 6.0
10 ga. 500 / 7.0 500 / 7.0 300 / 6.0 300 / 6.0 240 / 6.5 240 / 7.0 325 / 6.5 300 / 7.0
3/16 570 / 90 600 / 7.8 400 / 7.5 400 / 7.0
1/4 700 / 9.1 700 / 8.5
COMMENTS
Not
Recommended
below 400
WFS
Not
Recommended
below 400
WFS
MATERIAL THICKNESS
WFS / POWER MODE SETTING
TABLE B.2
Vue de la page 27