Vue de la page 0
MAGNUM 400 DUAL PROCEDURE
FM GUN & CABLE ASSEMBLIES
OPERATORʼS MANUAL
IM647-A
March, 2008
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However,
your overall safety can be
increased by proper installation
... and thoughtful operation on
your part. DO NOT INSTALL,
OPERATE OR REPAIR THIS
EQUIPMENT WITHOUT READ-
ING THIS MANUAL AND THE
SAFETY PRECAUTIONS CON-
TAINED THROUGHOUT. And,
most importantly, think before
you act and be careful.
Models
K575
K1723
K575
K1723
®
• Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
• World's Leader in Welding and Cutting Products •
Copyright © Lincoln Global Inc.
RETURN TO MAIN MENU
Vue de la page 0
1 2 3 4 5 6 ... 27 28

Résumé du contenu

Page 1 - FM GUN & CABLE ASSEMBLIES

MAGNUM 400 DUAL PROCEDUREFM GUN & CABLE ASSEMBLIESOPERATORʼS MANUALIM647-AMarch, 2008Safety Depends on YouLincoln arc welding and cuttingequipment

Page 2 - MAGNETIC FIELDS

A-3INSTALLATIONA-3Read this entire installation section before youstart installation.SAFETY PRECAUTIONSELECTRIC SHOCK can kill.• Do not touch electric

Page 3 - FUMES AND GASES

B-1OPERATIONB-1MAGNUM® 400 FM DUAL PROCEDURE GUNSELECTRODES AND EQUIPMENTThe Magnum® 400 Dual Procedure guns and cableshave been designed for use with

Page 4

D-1MAINTENANCED-1MAGNUM® 400 FM DUAL PROCEDURE GUNSNOTE: For KP42/44N and KP45N liner series. Before fully seating the liner bushing, it will be neces

Page 5 - REDRESSEUR

D-2MAINTENANCED-2MAGNUM® 400 FM DUAL PROCEDURE GUNSThis screw should only be gently tightened.Overtightening will split or collapse the liner andcause

Page 6 - Thank You

D-3MAINTENANCED-3MAGNUM® 400 FM DUAL PROCEDURE GUNSCABLECONTROL LEAD(4 CONTROL LEADS)CABLECONTROL LEADS(4 CONTROL LEADS)(41.9mm SKIN)1/4" (6.4mm)

Page 7

D-4MAINTENANCED-4MAGNUM® 400 FM DUAL PROCEDURE GUNSFigure E.4g) Check that the cable boot and both halves of thestrain relief are on the cable. Slip

Page 8

D-5MAINTENANCED-5MAGNUM® 400 FM DUAL PROCEDURE GUNSSWITCH WIREST0 RED LEADCABLE ASSEMBLYSTRAIN RELIEFSTRAIN RELIEF HOUSINGCABLE BOOTGUN TUBETRIGGER WI

Page 9

D-6MAINTENANCED-6MAGNUM® 400 FM DUAL PROCEDURE GUNSNOTE: For best results, insert a .219"/.240" (5.6-6.1 mm) diameter rod through the conne

Page 10 - INSTALLATION

D-7D-7MAGNUM® 400 FM DUAL PROCEDURE GUNSTHREAD SIZES FOR MAGNUM® 400 CONSUMABLESMAINTENANCE

Page 11 - OPERATION

E-1TROUBLESHOOTINGE-1MAGNUM® 400 FM DUAL PROCEDURE GUNSIf for any reason you do not understand the test procedures or are unable to perform the tests/

Page 12 - MAINTENANCE

FOR ENGINEpowered equipment.1.a. Turn the engine off before troubleshooting and maintenancework unless the maintenance work requires it to be running.

Page 13

E-2TROUBLESHOOTINGE-2MAGNUM® 400 FM DUAL PROCEDURE GUNSObserve all Safety Guidelines detailed throughout this manualIf for any reason you do not under

Page 14

E-3TROUBLESHOOTINGE-3MAGNUM® 400 FM DUAL PROCEDURE GUNSObserve all Safety Guidelines detailed throughout this manualIf for any reason you do not under

Page 15

NOTES MAGNUM® 400 FM DUAL PROCEDURE GUNS

Page 16

E-5NOTES MAGNUM® 400 FM DUAL PROCEDURE GUNSE-5

Page 17

NOTES MAGNUM® 400 FM DUAL PROCEDURE GUNS

Page 18

NOTES MAGNUM® 400 FM DUAL PROCEDURE GUNS

Page 19 - TROUBLESHOOTING

READ AND UNDERSTAND THE MANUFACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BEUSED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.SE REC

Page 20

LEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE PARA ESTE EQUIPAMENTO E AS PARTES DE USO, E SIGA ASPRÁTICAS DE SEGURANÇA DO EMPREGADOR.WARNINGAVISO DEPR

Page 21

• Sales and Service through Subsidiaries and Distributors Worldwide •Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB

Page 22 - NOTES

iiSAFETYiiARC RAYS can burn.4.a. Use a shield with the proper filter and coverplates to protect your eyes from sparks andthe rays of the arc when weld

Page 23

iiiSAFETYiiiFOR ELECTRICALLYpowered equipment.8.a. Turn off input power using the disconnectswitch at the fuse box before working onthe equipment.8.b.

Page 24

ivSAFETYivPRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instructionset les précautions de sûreté specifiques qui parra

Page 25

vvThank Youfor selecting a QUALITY product by Lincoln Electric. We want youto take pride in operating this Lincoln Electric Company product••• as much

Page 26

viviMAGNUM® 400 FM DUAL PROCEDURE GUNSPageInstallation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 27

A-1INSTALLATIONMAGNUM® 400 FM DUAL PROCEDURE GUNSA-1GENERAL DESCRIPTION• Do not touch electrically live partssuch as output terminals or internalwirin

Page 28

A-2INSTALLATION MAGNUM® 400 FM DUAL PROCEDURE GUNSA-2DescriptionGun Contact Tips GasProduct Cable Wire Size Standard Diffuser Gas Cable Gun TubeNumb