RED-D-ARC
E
EX350
i
i
IM764-A
November, 2007
Red-D-Arc Spec-Built Welding Equipment
This RED-D-ARC welder is built to RED-D-ARC
Extreme Duty
design specifications by Lincoln Electric.
Safety Depends on You
This welder is designed and built with safety in mind.
However, your overall safety can be increased by proper installation
... and thoughtful operation on your part.
DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT
WITHOUT READING THIS MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED THROUGHOUT.
And, most importantly, think before you act and be careful.
For use with machines having Code Numbers:
10945, 11487
North Americaʼs Largest Fleet of Welding Equipment
1-800-245-3660
OPERATORʼS MANUAL
RETURN TO MAIN MENU
Vue de la page 0
1 2 3 4 5 6 ... 39 40

Résumé du contenu

Page 1 - RED-D-ARC

RED-D-ARCEEX350iiIM764-ANovember, 2007Red-D-Arc Spec-Built Welding EquipmentThis RED-D-ARC welder is built to RED-D-ARCExtreme Dutydesign specificatio

Page 2 - MAGNETIC FIELDS

A-3INSTALLATION A-3LN-7 Connection Instructions • Turn the EX350i power switch “off”.• Connect the K480 control cable from the LN-7 tothe EX350i 1

Page 3 - FUMES AND GASES

A-4INSTALLATION A-4EX350iPARALLEL OPERATIONThe EX350i are operable in parallel in CC mode. Forbest results, the currents of each machine should ber

Page 4

B-1OPERATIONEX350iB-1SAFETY PRECAUTIONSELECTRIC SHOCK can kill.• Do not touch electrically live parts orelectrode with skin or wet clothing.• Insulate

Page 5 - REDRESSEUR

B-2OPERATIONB-25.THERMAL• This status light indicates when the power source hasbeen driven into thermal overload. If the output terminalswere "O

Page 6 - Thank You

B-3OPERATIONB-3TIG GTAW: The TIG mode features continuous con-trol from 5 to 425 amps. The TIG mode can be run ineither the TIG touch start or high fr

Page 7 - TABLE OF CONTENTS

B-4OPERATIONB-47A. ADVANCED PROCESS PANEL (See Figure 2)To program Welding modes. Select knob is used toScroll through all Welding modes. The Memory

Page 8 - Height Width Depth

B-5OPERATIONB-5EX350iCONTROLS: (See Figure 2)The MEMORY button and SELECT knob are usedtogether to select a welding process and store it inmemory (M1

Page 9

B-6OPERATIONB-6WELD MODE DETAILS:EX350iMode Range Comments Stick Soft 5 - 425 amps The stick soft mode is the best selection for general stick applica

Page 10 - INSTALLATION

B-7OPERATIONB-7PULSE PROGRAMS:EX350iMODE IMP*.030 Steel 65 - 1200.035 Steel 55 - 800.045 Steel 50 - 700.052 Steel 75 - 550.045 Metal Core 50 - 650.052

Page 11

B-8OPERATIONB-8EX350iLN-10/DH-10 Wire Feeder Compatibility Note:The LN-10 and DH-10 feeders can be used to pulseweld and in the power mode with the pa

Page 12 - OPERATION

FOR ENGINEpowered equipment.1.a. Turn the engine off before troubleshooting and maintenancework unless the maintenance work requires it to be running.

Page 13

B-9OPERATIONB-9EX350iAUXILIARY POWER• 115VAC, 42VAC and 24VAC power is availablefrom the two 14-pin amphenols on the rear of theunit. These supplies a

Page 14

C-1ACCESSORIESC-1OPTIONS / ACCESSORIES• K2176-1 Twist-Mate to Lug Adapter• K1764-1 Inverter and Feeder Cart• K1557 Swivel Kit• K1702-1 Dual Cylind

Page 15

D-1MAINTENANCED-1VISUAL INSPECTIONClean interior of machine with a low pressure airstream. Make a thorough inspection of all compo-nents. Look for s

Page 16

E-1TROUBLESHOOTINGE-1EX350iIf for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Page 17

E-2TROUBLESHOOTINGE-2EX350iIf for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Page 18

E-3TROUBLESHOOTINGE-3EX350iObserve all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the test procedures or

Page 19

E-4TROUBLESHOOTINGE-4EX350iObserve all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the test procedures or

Page 20

E-5TROUBLESHOOTINGE-5EX350iObserve all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the test procedures or

Page 21 - ACCESSORIES

F-1DIAGRAMSF-1EX350iTURN THE POWER SWITCH O THE WELDING POWERSOURCE O BE ORE INSTALLING PLUGS ON CABLESOR WHEN CONNECTING OR DISCONNECTING PLUGS TO

Page 22 - MAINTENANCE

F-2DIAGRAMSF-2EX350iN A WELDING CABLE MUST BE SI ED OR CURRENT AND DUTY CYCLE O APPLICATIONN B DIAGRAM SHOWS ELECTRODE POSITI E TO CHANGE POLA

Page 23 - TROUBLESHOOTING

iiSAFETYiiARC RAYS can burn.4.a. Use a shield with the proper filter and coverplates to protect your eyes from sparks andthe rays of the arc when weld

Page 24

F-3DIAGRAMSF-3EX350iN A WELDING CABLE MUST BE SI ED OR CURRENT AND DUTY CYCLE O APPLICATIONN B DIAGRAM SHOWS ELECTRODE POSITI E TO CHANGE POLA

Page 25

F-4DIAGRAMSF-4EX350iN.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POL

Page 26

F-5DIAGRAMSF-5EX350iO WARNINGT W P SB ELECTRICSHOCKCAN KILLN A WELDING CABLE MUST BE SI ED OR CURRENT AND DUTY CYCL

Page 27

F-6DIAGRAMSF-6EX350iO WARNINGT W P SB ELECTRICSHOCKCAN KILLN A WELDING CABLE MUST BE SI ED OR CURRENT AND DUTY CYCL

Page 28 - DIAGRAMS

F-7DIAGRAMSF-7EX350iNOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram

Page 29

F-8DIAGRAMSF-8EX350iNOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram

Page 30

F-9DIMENSION PRINTF-9EX350iM195276-0114.7912.443.4421.0627.825.5010.00MOUNTING HOLE LOCATIONS13.101/4-20 NUT (4 PLACES)NOTE: MOUNTING SCREWS CANNOT P

Page 31

NOTES EX350I

Page 32

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicREAD AND UNDERSTAND THE MANUFACTURER’S INSTRUC

Page 33

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicLEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE

Page 34

iiiSAFETYiiiFOR ELECTRICALLYpowered equipment.8.a. Turn off input power using the disconnectswitch at the fuse box before working onthe equipment.8.b.

Page 35

• Sales and Service through Subsidiaries and Distributors Worldwide •Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB

Page 36 - DIMENSION PRINT

ivSAFETYivPRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instruc-tions et les précautions de sûreté specifiques qui par

Page 37 - NOTES

vvThank Youfor selecting a QUALITY product. We want you to take pride inoperating this product ••• as much pride as we have in bringingthis product to

Page 38

vi vi TABLE OF CONTENTSPageInstallation ...Section

Page 39

EX350iA-1INSTALLATION A-1TECHNICAL SPECIFICATIONS - RED-D-ARC EX350iINPUT AC VOLTAGE & DC OUTPUT* Overall Length Including Handle, 27.8” (706mm)

Page 40

A-2INSTALLATION A-2SELECT SUITABLE LOCATIONThe EX350i will operate in harsh environments. Evenso, it is important that simple preventative measuresa